{"id":58,"date":"2026-08-06T15:22:37","date_gmt":"2026-08-06T12:22:37","guid":{"rendered":"http:\/\/localhost:8080\/?p=58"},"modified":"2026-08-06T15:22:37","modified_gmt":"2026-08-06T12:22:37","slug":"elcla-models-2","status":"publish","type":"post","link":"https:\/\/bioexpert.ee\/en\/uncategorized\/elcla-models-2\/","title":{"rendered":"Elcla models"},"content":{"rendered":"<figure class=\"wp-block-image size-full\"><img decoding=\"async\" src=\"http:\/\/localhost:8080\/wp-content\/uploads\/2026\/08\/image-1.png\" alt=\"\" class=\"wp-image-53\"\/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Elclamini operates at a water flow rate of up to 1 m3\/h and is designed for installation on individual heating devices directly in front of the devices (washing machines, dishwashers, boilers), but is also suitable for apartments (in case of short piping).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Elcla 1 and 2 are suitable for use in private houses, Elcla 2 also for smaller apartment buildings.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The largest Elcla devices are designed for a maximum flow rate of up to 39 m3\/h (650 l\/min). For even higher flow rates, a bypass with two or more Elcla devices is used.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Device selection<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The Elcla magnetic water treatment device model must be selected according to 2 main indicators:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>maximum water flow rate during peak water consumption (m3\/h, l\/s),<\/li>\n\n\n\n<li>water pipe diameter.<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">In the case of a recirculation system, the second Elcla device in the system must be selected according to the recirculation pump capacity (m3\/h, l\/s). Generally, an Elcla device with the same thread diameter as the water pipe is installed, but with the calculation that the existing peak water consumption does not exceed the maximum flow intensity allowed for the device.<br>If the maximum flow intensity is significantly lower than the diameter of the existing pipe would allow, then an Elcla with a smaller thread diameter can be installed with a bypass, which is suitable for the maximum intensity of the existing water flow.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In the case of larger consumers, in order to select an Elcla device, the buyer\/customer of the device must submit to AS Bioexperdi:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>a brief description of the water consumer and a general diagram of the water and heating system,<\/li>\n\n\n\n<li>the diameter of the water pipe at the building&#8217;s water inlet and before the heating device (heat exchanger),<\/li>\n\n\n\n<li>the maximum water consumption during peak hours (m3\/h or l\/s),<\/li>\n\n\n\n<li>if there is a recirculation pump, its productivity (m3\/h or l\/s),<\/li>\n\n\n\n<li>the results of water analysis (water hardness, iron content, pH, free CO2 and aggressive CO2 content).<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Technical data<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The normal operating pressure of Elcla devices is 3 to 6 bar (PN16).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The threads of the devices are from \u00bd\u201d to 4\u201d inches in diameter, 71 to 260 mm in length and 0.2 to 19.3 kg in weight.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The three largest devices are flanged (bolted).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The devices cause some current loss according to their construction. Diagrams have been prepared for this (up to Elcla 5).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The residual induction of the Elcla permanent magnet (ferrite) is 3900 Gauss, in the case of Elclamin (Nd-Fe-B magnet) \u2013 14,000 Gauss, which practically does not change over time.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Elcla magnetic devices are not afraid of temperature increases up to 450 degrees, Elclamin \u2013 up to 310 degrees. The devices must not be subjected to shocks.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The device gives the best effect when it is installed on a cold water pipe and the water temperature increases when heated, but not more than 80 degrees. Elcla also works when used only with cold or only with warm water. At high temperatures, especially above 90 degrees, the effect of magnetic treatment of water begins to decrease.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The effect of Elcla is maintained in pipelines of hundreds of meters (for example, in factories). In the pipeline, under pressure, the effect of the magnetic field persists for 48 hours, when leaving the pipeline &#8211; less. In the case of a single device, it is recommended to install Elcla as close as possible to the device.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Composition of the Elcla device<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>body: forged brass, white copper &#8211; OT58 type, coated with nickel\/chrome;<\/li>\n\n\n\n<li>diffusion grid in forging &#8211; OT58 type, coated with nickel;<\/li>\n\n\n\n<li>magnetic separators are located in stainless steel,<\/li>\n\n\n\n<li>permanent magnets are oriented in anisotropic ferrite.<\/li>\n\n\n\n<li>gasket &#8211; circular.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Elclamin permanent magnet is of neodymium-iron-boron composition.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Warranty<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Elcla devices have a 10-year warranty against technical defects in the product. Defective products will be replaced by the factory. In general, Elcla magnetic devices must last as long as the pipes and houses in which they are used.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">About the manufacturer<\/p>","protected":false},"excerpt":{"rendered":"<p>Elclamini operates at a water flow rate of up to 1 m3\/h and is designed for installation on individual heating devices directly in front of the devices (washing machines, dishwashers, boilers), but is also suitable for apartments (in case of short piping). Elcla 1 and 2 are suitable for use in private houses, Elcla 2 [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-58","post","type-post","status-publish","format-standard","hentry","category-uncategorized"],"_links":{"self":[{"href":"https:\/\/bioexpert.ee\/en\/wp-json\/wp\/v2\/posts\/58","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/bioexpert.ee\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/bioexpert.ee\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/bioexpert.ee\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/bioexpert.ee\/en\/wp-json\/wp\/v2\/comments?post=58"}],"version-history":[{"count":1,"href":"https:\/\/bioexpert.ee\/en\/wp-json\/wp\/v2\/posts\/58\/revisions"}],"predecessor-version":[{"id":60,"href":"https:\/\/bioexpert.ee\/en\/wp-json\/wp\/v2\/posts\/58\/revisions\/60"}],"wp:attachment":[{"href":"https:\/\/bioexpert.ee\/en\/wp-json\/wp\/v2\/media?parent=58"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/bioexpert.ee\/en\/wp-json\/wp\/v2\/categories?post=58"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/bioexpert.ee\/en\/wp-json\/wp\/v2\/tags?post=58"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}